Temperature Controller
OPTIONAL RS232 Interface
Hardware
Standard three pin hookup, 2,3,5, on DB9.
Baud rate 9600,N,8,1.
No handshaking.
Software
ASCII letters followed by a delimiter and carriage return (ASCII 13).
Commands from Host to Controller:
Request Current Temperature
xxx-temperature Carriage Return (13)
Communications from Controller to Host:
Power has been switched off
Door Switch is Open/Closed
Received Set command, Executed OK
Can not understand Command
xxx-temperature Carriage Return (13)
Notes:
All temperatures are in Fahrenheit.
Host program to convert to Celsius if required.
G,H,I,J are sent every few seconds when those levels have been tripped.
S is sent upon change of state.
M is sent upon shock sensor being tripped.
Temperature set range is from 1 to 190°, Fahrenheit.
Return temperature has a space after the „T‟ if positive, a – if negative.
Return temperature range is –140° to +190°.