01-07 3
tel: 303.412.0399 www.displaydevices.com
fax: 303.412.9346 tech@displaydevices.com
5880 Sheridan Blvd., Arvada, Colorado 80003
4.) Raise the unit up on a material lift to the appropriate vertical height. Be sure to have a
sufficient amount of threaded rod to provide leveling room. Add hardware as follows for
leveling: above unit – nut/lock washer/flat washer; underside of unit – washer and nut - do
not tighten yet.
5.) Use a bubble level to level the unit front-to-back and side-to-side. Tighten hardware.
6.) To attach the fire dampers to the intake and exhaust ports use the enclosed Phillips-head
sheet metal screws.
7.) Add runs of ductwork on the intake and exhaust fire dampers. Addition of ducts disperses
the sound further away from the projector. Sound-isolating ductwork is recommended. If
additional sound dampening is desired, we recommend an auto sound insulation material.
8.) Mounting points for a projector mount or lift are pre-installed inside the top of the cavity. The
structural channel can be loosened and adjusted for the proper width of the mount or lift.
Mounting rails with
pre-installed rods
(under plate)